# Consistency of annual reporting

Whether reported numbers that should be related agree: ANC1 with penta1, penta1 with penta3, and OPV1 with OPV3, nationally and by district.

Some reported numbers should be related. Most women who make a first antenatal visit
(*ANC1* (The first antenatal care visit of a pregnancy, usually at about 20 weeks (4-5 months) of pregnancy.)) give birth to a baby who later receives the first dose of pentavalent vaccine
(*penta1* (The first and third doses of pentavalent (DTP-containing) vaccine, recommended at 6 and 14 weeks of age.)); most children who receive penta1 go on to receive penta3. This
check compares their annual totals with the ratio expected between them.

> **Note**
>
> **At a glance**
> - **Compares:** ANC1 with penta1, penta1 with penta3, and for vaccines *OPV1 with OPV3* (The first and third doses of oral polio vaccine.).
> - **Good result:** each national ratio within ± 0.05 of its *expected ratio* (The ratio of two reported numbers (such as ANC1 to penta1) implied by the survey coverage and, for ANC1 to penta1, the mortality between the two; a national ratio within plus or minus 0.05 of it is acceptable.); most districts with ratios between 1.0 and 1.5.
> - **In the app:** the **[Internal Consistency](https://datasuite.damurka.com/en/apps/countdown/data-quality/internal-consistency.md)** page of the data quality pages (**Ratio Plots** and **Consistency Checks**).

## Why

There is often an inconsistency between antenatal and immunization data, even though the two should be consistent.
Examining the association between ANC1 and penta1 is particularly informative: a number can be complete and free of
outliers and still be wrong, and only a comparison with a related number shows it.

## What

| Indicator | Numerator | Denominator | Interpretation |
| --- | --- | --- | --- |
| ANC1 to penta1 ratio in the reported data (national) | Number of ANC1 reported | Number of penta1 reported | National ratio within an expected range (see [Expected ratios](#expected-ratios)) |
| Penta1 to penta3 ratio in the reported data (national) | Number of penta1 reported | Number of penta3 reported | National ratio within an expected range, based on the survey results |
| OPV1 to OPV3 ratio in the reported data (national; vaccines) | Number of OPV1 reported | Number of OPV3 reported | National ratio within an expected range, based on the survey results |
| % of districts with the ratio between 1.0 and 1.5 (one for each ratio above) | Number of districts with ratios within the expected range | Total number of districts | For districts there is more variation in the ratio: a wider range is considered |

## Expected ratios

**ANC1 to penta1.** ANC1 takes place at about 20 weeks of pregnancy and penta1 at 6-8 weeks after birth. In between, the
method assumes a *pregnancy loss* (A pregnancy that ends before birth (miscarriage or abortion).) of 3%, a
*stillbirth* (A baby born with no signs of life after 28 weeks of pregnancy.) rate of 2%, a *twinning rate* (The share of births that are twins.)
of 1.5% and *neonatal mortality* (Deaths of babies in their first 28 days of life.) before penta1 of 3%. For every 100 women
at ANC1 there are then

$$100 \times (1 - 0.03 - 0.02 + 0.015 - 0.03) = 93.5 \text{ infants at penta1}$$

so the ratio is $100 \div 93.5 = 1.07$ when ANC1 and penta1 coverage are the same. The actual coverage of both, from the
most recent *household survey* (A national survey, such as a DHS or MICS, that measures coverage by interviewing a sample of households. Its coverage figures are used as a benchmark for the facility data.), is then taken into account:

$$E_{\text{ANC1/penta1}} = 1.07 \times \frac{C_{ANC1}}{C_{penta1}}$$

*Worked example:* survey coverage of 90% for ANC1 and 95% for penta1 gives 1.07 × 0.90 ÷ 0.95 = **1.01**; reported ratios
from **0.96 to 1.06** are acceptable.

**Penta1 to penta3** (and **OPV1 to OPV3**). The doses are given at 6 and 14 weeks of age; few children die in between,
so the main factor is the *drop-out* (Children who received the first dose minus those who received the second, divided by the first, as a percentage.) between the doses. The expected ratio comes
from the latest survey:

$$E_{\text{penta1/penta3}} = \frac{C_{penta1}}{C_{penta3}}$$

*Worked example:* survey coverage of 95% for penta1 and 85% for penta3 gives 0.95 ÷ 0.85 = **1.12**; reported ratios from
**1.07 to 1.17** are acceptable.

## Formula

$$\text{Ratio} = \frac{N_{1}}{N_{2}}$$

A national ratio is acceptable when it is within 0.05 of its expected ratio $E$:

$$\lvert \text{Ratio} - E \rvert \le 0.05$$

For districts, the share whose ratio is in the wider range:

$$\text{Districts in range} = \frac{\text{number of districts with } 1.0 \le \text{Ratio} \le 1.5}{D} \times 100$$

where

- $N_{1}$ and $N_{2}$ are the two reported annual numbers (for example ANC1 and penta1);
- $C$ is a coverage rate from the most recent survey;
- $D$ is the total number of districts.

## Settings

| Setting | Default | What it means |
| --- | --- | --- |
| National tolerance | ± 0.05 | How far a national ratio may be from its expected ratio. |
| District range | 1.0 to 1.5 | The range a district's ratio must be in. |
| Mortality factor | 1.07 | The ANC1 to penta1 ratio expected when both have the same coverage (above). |

If no survey coverage is entered, the expected ratios assume coverage of 98% for ANC1, 97% for penta1 and OPV1, 89% for
penta3 and 78% for OPV3; enter the country's survey values in [Analysis setup](https://datasuite.damurka.com/en/methodology/analysis-setup.md).

## Interpretation

- **Is a national ratio outside its range?** Flag it, and discuss possible explanations before adjusting anything.
- **Are there large differences between years** (more than 0.10, or 10%)? Reflect on what changed, in services or in reporting.
- **Which districts are far from the diagonal** in the consistency plots? For instance, districts where ANC1 is much higher than penta1.
- **Is the survey value right?** The expected ratios come from the survey, so a wrong survey value makes good data look inconsistent.
- Not every deviation is a data problem: an unusual penta1 to penta3 ratio can be real drop-out, and campaigns or service disruptions can explain differences.

### Example: national ratios against their expected values

![ANC1 to penta1 and penta1 to penta3 ratios by year, compared with the expected ratios](https://datasuite.damurka.com/images/dqa-out-ratios.png)

**Reading the chart:** each bar is a year's reported ratio; the last bar of each group (pink) is the expected ratio. The
dashed lines mark 1.0 and 1.5, the range used for districts.

**What it shows:** the ANC1 to penta1 ratio is between **1.35 and 1.43** every year, against an expected **1.04**: far
outside the acceptable 0.99 to 1.09. Many more ANC1 visits are reported than penta1 doses: either ANC1 is over-reported
(for example, later antenatal visits counted as first visits) or penta1 is under-reported. This needs to be discussed
before antenatal or vaccination coverage is used. The penta1 to penta3 ratio is between **1.06 and 1.10**, below its
expected **1.21** (acceptable 1.16 to 1.26): the reported drop-out is smaller than the survey suggests.

### Example: ANC1 and penta1, district by district

![Penta1 against ANC1 for each district, by year](https://datasuite.damurka.com/images/dqa-out-anc1-penta1.png)

**Reading the chart:** each dot is a district, with its ANC1 (across) and penta1 (up). On the red dashed diagonal the two
would be equal; the black line follows the districts.

**What it shows:** the districts lie below the diagonal, and further below it the larger the district: the gap between
ANC1 and penta1 is found in almost every district, not in one or two. The districts follow the line closely every year
(R² about 0.95 to 0.97), so the pattern is systematic.

### Example: penta1 and penta3, district by district

![Penta3 against penta1 for each district, by year](https://datasuite.damurka.com/images/dqa-out-penta1-penta3.png)

**Reading the chart:** as above, with penta1 across and penta3 up.

**What it shows:** the districts lie almost on the diagonal, very closely every year (R² about 0.99): penta1 and penta3
are consistent in every district, with little drop-out.

## After the assessment

Consistency is not corrected automatically. Its results feed the
[annual data quality score](https://datasuite.damurka.com/en/methodology/data-quality/quality-score.md) and help decide, in
[Data adjustment](https://datasuite.damurka.com/en/methodology/data-adjustment.md), whether a year or a district can be used.